Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Breath Res ; 18(2)2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38467063

RESUMO

Volatilomics is a powerful tool capable of providing novel biomarkers for the diagnosis of gastric cancer. The main objective of this study was to characterize the volatilomic signatures of gastric juice in order to identify potential alterations induced by gastric cancer. Gas chromatography with mass spectrometric detection, coupled with headspace solid phase microextraction as the pre-concentration technique, was used to identify volatile organic compounds (VOCs) released by gastric juice samples collected from 78 gastric cancer patients and two cohorts of controls (80 and 96 subjects) from four different locations (Latvia, Ukraine, Brazil, and Colombia). 1440 distinct compounds were identified in samples obtained from patients and 1422 in samples provided by controls. However, only 6% of the VOCs exhibited an incidence higher than 20%. Amongst the volatiles emitted, 18 showed differences in their headspace concentrations above gastric juice of cancer patients and controls. Ten of these (1-propanol, 2,3-butanedione, 2-pentanone, benzeneacetaldehyde, 3-methylbutanal, butylated hydroxytoluene, 2-pentyl-furan, 2-ethylhexanal, 2-methylpropanal and phenol) appeared at significantly higher levels in the headspace of the gastric juice samples obtained from patients; whereas, eight species showed lower abundance in patients than found in controls. Given that the difference in the volatilomic signatures can be explained by cancer-related changes in the activity of certain enzymes or pathways, the former set can be considered potential biomarkers for gastric cancer, which may assist in developing non-invasive breath tests for the diagnosis of this disease. Further studies are required to elucidate further the mechanisms that underlie the changes in the volatilomic profile as a result of gastric cancer.


Assuntos
Neoplasias Gástricas , Compostos Orgânicos Voláteis , Humanos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Testes Respiratórios/métodos , Biomarcadores/análise , Compostos Orgânicos Voláteis/análise , Microextração em Fase Sólida/métodos , Suco Gástrico/metabolismo
2.
Int J Mol Sci ; 25(3)2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38338911

RESUMO

The human body emits a multitude of volatile organic compounds (VOCs) via tissues and various bodily fluids or exhaled breath. These compounds collectively create a distinctive chemical profile, which can potentially be employed to identify changes in human metabolism associated with colorectal cancer (CRC) and, consequently, facilitate the diagnosis of this disease. The main goal of this study was to investigate and characterize the VOCs' chemical patterns associated with the breath of CRC patients and controls and identify potential expiratory markers of this disease. For this purpose, gas chromatography-mass spectrometry was applied. Collectively, 1656 distinct compounds were identified in the breath samples provided by 152 subjects. Twenty-two statistically significant VOCs (p-xylene; hexanal; 2-methyl-1,3-dioxolane; 2,2,4-trimethyl-1,3-pentanediol diisobutyrate; hexadecane; nonane; ethylbenzene; cyclohexanone; diethyl phthalate; 6-methyl-5-hepten-2-one; tetrahydro-2H-pyran-2-one; 2-butanone; benzaldehyde; dodecanal; benzothiazole; tetradecane; 1-dodecanol; 1-benzene; 3-methylcyclopentyl acetate; 1-nonene; toluene) were observed at higher concentrations in the exhaled breath of the CRC group. The elevated levels of these VOCs in CRC patients' breath suggest the potential for these compounds to serve as biomarkers for CRC.


Assuntos
Neoplasias Colorretais , Compostos Orgânicos Voláteis , Humanos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Testes Respiratórios/métodos , Compostos Orgânicos Voláteis/metabolismo , Biomarcadores/análise , Neoplasias Colorretais/diagnóstico
3.
Diagnostics (Basel) ; 13(21)2023 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-37958251

RESUMO

Colorectal cancer (CRC) is the third most common malignancy and the second most common cause of cancer-related deaths worldwide. While CRC screening is already part of organized programs in many countries, there remains a need for improved screening tools. In recent years, a potential approach for cancer diagnosis has emerged via the analysis of volatile organic compounds (VOCs) using sensor technologies. The main goal of this study was to demonstrate and evaluate the diagnostic potential of a table-top breath analyzer for detecting CRC. Breath sampling was conducted and CRC vs. non-cancer groups (105 patients with CRC, 186 non-cancer subjects) were included in analysis. The obtained data were analyzed using supervised machine learning methods (i.e., Random Forest, C4.5, Artificial Neural Network, and Naïve Bayes). Superior accuracy was achieved using Random Forest and Evolutionary Search for Features (79.3%, sensitivity 53.3%, specificity 93.0%, AUC ROC 0.734), and Artificial Neural Networks and Greedy Search for Features (78.2%, sensitivity 43.3%, specificity 96.5%, AUC ROC 0.735). Our results confirm the potential of the developed breath analyzer as a promising tool for identifying and categorizing CRC within a point-of-care clinical context. The combination of MOX sensors provided promising results in distinguishing healthy vs. diseased breath samples. Its capacity for rapid, non-invasive, and targeted CRC detection suggests encouraging prospects for future clinical screening applications.

4.
Diagnostics (Basel) ; 13(10)2023 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-37238155

RESUMO

As of today, there is a lack of a perfect non-invasive test for the surveillance of patients for potential relapse following curative treatment. Breath volatile organic compounds (VOCs) have been demonstrated to be an accurate diagnostic tool for gastric cancer (GC) detection; here, we aimed to prove the yield of the markers in surveillance, i.e., following curative surgical management. Patients were sampled in regular intervals before and within 3 years following curative surgery for GC; gas chromatography-mass spectrometry (GC-MS) and nanosensor technologies were used for the VOC assessment. GC-MS measurements revealed a single VOC (14b-Pregnane) that significantly decreased at 12 months, and three VOCs (Isochiapin B, Dotriacontane, Threitol, 2-O-octyl-) that decreased at 18 months following surgery. The nanomaterial-based sensors S9 and S14 revealed changes in the breath VOC content 9 months after surgery. Our study results confirm the cancer origin of the particular VOCs, as well as suggest the value of breath VOC testing for cancer patient surveillance, either during the treatment phase or thereafter, for potential relapse.

5.
Molecules ; 28(8)2023 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-37110724

RESUMO

It has been shown that the gut microbiota plays a central role in human health and disease. A wide range of volatile metabolites present in exhaled breath have been linked with gut microbiota and proposed as a non-invasive marker for monitoring pathological conditions. The aim of this study was to examine the possible correlation between volatile organic compounds (VOCs) in exhaled breath and the fecal microbiome by multivariate statistical analysis in gastric cancer patients (n = 16) and healthy controls (n = 33). Shotgun metagenomic sequencing was used to characterize the fecal microbiota. Breath-VOC profiles in the same participants were identified by an untargeted gas chromatography-mass spectrometry (GC-MS) technique. A multivariate statistical approach involving a canonical correlation analysis (CCA) and sparse principal component analysis identified the significant relationship between the breath VOCs and fecal microbiota. This relation was found to differ between gastric cancer patients and healthy controls. In 16 cancer cases, 14 distinct metabolites identified from the breath belonging to hydrocarbons, alcohols, aromatics, ketones, ethers, and organosulfur compounds were highly correlated with 33 fecal bacterial taxa (correlation of 0.891, p-value 0.045), whereas in 33 healthy controls, 7 volatile metabolites belonging to alcohols, aldehydes, esters, phenols, and benzamide derivatives correlated with 17 bacterial taxa (correlation of 0.871, p-value 0.0007). This study suggested that the correlation between fecal microbiota and breath VOCs was effective in identifying exhaled volatile metabolites and the functional effects of microbiome, thus helping to understand cancer-related changes and improving the survival and life expectancy in gastric cancer patients.


Assuntos
Microbioma Gastrointestinal , Neoplasias Gástricas , Compostos Orgânicos Voláteis , Humanos , Neoplasias Gástricas/diagnóstico , Cromatografia Gasosa-Espectrometria de Massas , Compostos Orgânicos Voláteis/análise , Fezes/química
6.
Artigo em Inglês | MEDLINE | ID: mdl-36554357

RESUMO

This study explored the effects of partly supervised physical exercise program (PSPEP) intervention compared to fully supervised physical exercise program (FSPEP) on cognitive functions, movement proficiency and problematic internet use (PIU) in adolescents presenting combined unhealthy lifestyle behaviors. METHOD: Over a period of 16 weeks the PSPEP group (n = 14) engaged in strength, balance and flexibility exercises three times per week with one supervised session and two unsupervised. The FSPEP group (n = 13) practiced dance activities for 2 to 4 days per week including in training sessions the same exercises as for the PSPEP group. Prior and after the study adolescents completed the PIU scale, performed movement proficiency and cognitive function tests. RESULTS: The PSPEP had significant effect on improvement of stress tolerance (p < 0.01, g = 1.08), while the FSPEP had significant effect on contributing general intelligence (p < 0.05, g = 0.90), color-word interference of the reading speed or color recognition (p < 0.01, g = 1.33), short- and long-term memory (p < 0.01, g = 1.72) and stress tolerance (p < 0.05, g = 1.06). The PSPEP had significant effect on improvement of the bilateral coordination (p < 0.01, g = 1.08). None of the two programs had effect on PIU. CONCLUSIONS: Engagement in PSPEP selectively contributed bilateral coordination and cognitive skills related to reaction to multiple stimuli. The FSPEP had multiple significant effects in improvement of cognitive outcomes.


Assuntos
Cognição , Exercício Físico , Humanos , Adolescente , Exercício Físico/psicologia , Terapia por Exercício , Modalidades de Fisioterapia , Estilo de Vida
7.
Diagnostics (Basel) ; 12(2)2022 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-35204521

RESUMO

BACKGROUND: The need for mechanical lung ventilation is common in critically ill patients, either with COVID-19 infection or due to other causes. Monitoring of patients being ventilated is essential for timely and improved management. We here propose the use of a novel breath volatile organic compound sensor technology to be used in a mechanical lung ventilation machine for this purpose; the technology was evaluated in critically ill COVID-19 patients on mechanical lung ventilation. METHODS: Based on the consistency results of our study data, the breath sensor device with metal oxide gas sensors and environment-controlling sensors was mounted on the ventilation exhaust port of the ventilation machine; this allowed to ensure additional safety since the device was placed outside the contour between the patient and equipment. RESULTS: The sensors allowed stable registration of the signals for up to several weeks for 10 patients in total, depending on the storage amount; a proportion of patients were intubated or received tracheostoma during the evaluation period. Future studies are on the way to correlate sensor readings to other parameters characterizing the severity of the patient condition and outcome. CONCLUSIONS: We suppose that such technology will allow patient monitoring in real-time for timely identification of deterioration, potentially requiring some change of management. The obtained results are preliminary and further studies are needed to examine their clinical significance.

8.
Diagnostics (Basel) ; 12(2)2022 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-35204584

RESUMO

BACKGROUND: Gastric cancer is one of the deadliest malignant diseases, and the non-invasive screening and diagnostics options for it are limited. In this article, we present a multi-modular device for breath analysis coupled with a machine learning approach for the detection of cancer-specific breath from the shapes of sensor response curves (taxonomies of clusters). METHODS: We analyzed the breaths of 54 gastric cancer patients and 85 control group participants. The analysis was carried out using a breath analyzer with gold nanoparticle and metal oxide sensors. The response of the sensors was analyzed on the basis of the curve shapes and other features commonly used for comparison. These features were then used to train machine learning models using Naïve Bayes classifiers, Support Vector Machines and Random Forests. RESULTS: The accuracy of the trained models reached 77.8% (sensitivity: up to 66.54%; specificity: up to 92.39%). The use of the proposed shape-based features improved the accuracy in most cases, especially the overall accuracy and sensitivity. CONCLUSIONS: The results show that this point-of-care breath analyzer and data analysis approach constitute a promising combination for the detection of gastric cancer-specific breath. The cluster taxonomy-based sensor reaction curve representation improved the results, and could be used in other similar applications.

9.
Molecules ; 26(12)2021 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-34205805

RESUMO

Exhaled breath analysis for early disease detection may provide a convenient method for painless and non-invasive diagnosis. In this work, a novel, compact and easy-to-use breath analyzer platform with a modular sensing chamber and direct breath sampling unit is presented. The developed analyzer system comprises a compact, low volume, temperature-controlled sensing chamber in three modules that can host any type of resistive gas sensor arrays. Furthermore, in this study three modular breath analyzers are explicitly tested for reproducibility in a real-life breath analysis experiment with several calibration transfer (CT) techniques using transfer samples from the experiment. The experiment consists of classifying breath samples from 15 subjects before and after eating a specific meal using three instruments. We investigate the possibility to transfer calibration models across instruments using transfer samples from the experiment under study, since representative samples of human breath at some conditions are difficult to simulate in a laboratory. For example, exhaled breath from subjects suffering from a disease for which the biomarkers are mostly unknown. Results show that many transfer samples of all the classes under study (in our case meal/no meal) are needed, although some CT methods present reasonably good results with only one class.


Assuntos
Técnicas Biossensoriais/métodos , Testes Respiratórios/métodos , Expiração/fisiologia , Sistema Respiratório/fisiopatologia , Adolescente , Biomarcadores/metabolismo , Calibragem , Humanos , Sistema Respiratório/metabolismo
10.
Bioelectromagnetics ; 25(3): 211-5, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15042630

RESUMO

The aim of the present study was to identify the effects of a static magnetic field (SMF) on rat brain structures that control autonomic functions, specifically heart rate and heart rhythmicity. The experiments were carried out on 44 male Wistar rats under ketamine-xylazine anesthesia. SMF was induced using samarium-cobalt fused magnets (20 x 20 x 10 mm in size) placed bitemporally. Magnetic induction intensity was 100 mT on the surface of the head. Duration of magnetic field application was 15 min. An electrocardiogram was recorded from limb lead II, and both heart rate (average duration of cardiac cycles) and heart rhythmicity were analyzed before and after SMF application. SMF evoked changes in both heart rate and rhythm in 80% of the animals; the predominant effects were bradycardia and disappearance of respiratory sinus arrhythmia. However, the effectiveness of SMF in large measure depends on both functional peculiarities and functional activities of brain autonomic centers.


Assuntos
Encéfalo/fisiologia , Frequência Cardíaca , Magnetismo , Animais , Eletrocardiografia , Masculino , Ratos , Ratos Wistar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...